BIT Fact Sheets

BIT Factsheets

This page provides you with the BIT fact sheets.

Fact Sheet Load Balanced Shared Webhosting

Click here to see the fact sheet for load balanced shared webhosting

 

Platform
  • Ubuntu 22.04.1 (http-linux-one) / Apache / PHP 8.1
  • Ubuntu 24.04.1 (http-linux-two) / Apache / PHP 8.3
  • MySQL 8 / phpMyAdmin
Hostnames/IP’s
  • http-linux-one.lb.network.bit.nl / 213.136.12.232 (IPv4) / 2001:7b8:3:5::80:1 (IPv6)
  • http-linux-two.lb.network.bit.nl / 213.136.12.251 (IPv4) / 2001:7b8:3:5::80:10 (IPv6)
  • mysql8.bit.nl
Access upload.bit.nl (accesible via: FTPS/SFTP/SCP/RSYNC/restricted SSH)
Data From 10 GB storage, 250GB traffic per maand
SSL
  • Standard Let’s Encrypt Domain Validated SSL-certificte per hostname/server alias.
  • Optional SSL-offloading VIP for other SSL-certificates upon request.
Backup Your web space and database data are regularly backed up to a redundant backup platform.

  • Your website data is backed up once a day. The backup retention is 7 days and 4 weeks: we have standard backups of the past 7 days, plus the 4 previous Mondays. We do this by taking snapshots and storing only changed data.
  • Your databases are backed up 3 times a day. You can go back to midnight, early morning or early evening backups.

 

Technical Specifications of the BIT Data Centres

Click here to see the techical specs for the BIT data centres

 

Construction data centre
Height service area minimum of 6 metres above NAP
Parking own parking spaces
Amenities vending machine for snacks and soda
coffee machine
workspaces
meeting rooms
Floor load 1500 kg/m²
Rack size 46 HU high, 60 cm wide, 100 cm deep
Fire detection an independent, certified, very early warning system with automated notification to the fire department
Fire extinguishing certified Argonite (Ar+N²) installation
Cooling system N+1 computairs
N+1 cooling machines
Cooling capacity 1500 W/m²
Temperature 27 ℃ (+/- 2 ℃) in cold corridors
Lightning protection certified according to NEN standards
Water detection water detection sensors under the floor
Electrical installation two incoming feeds into each rack
separate UPS for every feed
Emergency power supply N+1 diesel generators
Fuel supply 48 hours
Power per rack up to 96 A
Information Security ISO/IEC 27001 and NEN 7510 certified
Physical security VEB certified safety class 4*
Alarm redundant connection to control centre
Surveillance two independent surveillance services
Cameras inside and outside the data centres
Access control two-factor authentication
biometrics
RFID access cards
Service Level Agreement security
climate
power supply